O 2: 0 – 2000 ppm (readings will display higher levels)

#FAST 1.0 BAD OX SENSOR FULL#

Up to 90% Relative Humidity, Non-Condensingįunctional Specifications* Full Scale Measurement Range Physical and Electrical Specifications Size of Footprint Multiple H2 sensors can be provided with the CAM-12S for different CO2 levels, enabling sensor swapping in the anaerobic chamber as needed. For CO2 levels greater than 20%, a factory-set specific CO2 level compensation is available by ordering the CAM-12S. The user can compensate by inputting the background CO2 level up to 20% so that the appropriate offset can be applied to allow for accurate H2 measurement. However, the H2 sensor may be affected by CO2. Too little H2 will affect the ability to maintain low O2 and high H2 levels are potentially dangerous.ĬO2 Compensation – The CAM-12 O2 sensor is unaffected by CO2 or changes in CO2 levels. H2 alarms for both low and high H2 can be set to trigger before reaching undesirable levels for safety and function.

#FAST 1.0 BAD OX SENSOR DOWNLOAD#

Sensor calibration data is kept on the sensors so a fast download of new sensor data to the CAM-12 is all it takes to get accurate measurements.Īdjustable Alarms – The high O2 alarm is adjustable through the full scale of the sensor allowing monitoring to be set to match organism requirements. User Replaceable Sensors – Access through the rear panel allows easy and quick sensor swap for re-calibration or replacement in the anaerobic chamber without downtime.

fast 1.0 bad ox sensor

The security of knowing that an incorrect gas mixture can’t jeopardize your equipment or your safety is priceless. Each analyzer is especially calibrated to your specific background gas mix. Now labs who might otherwise have wanted separate, costly equipment to measure hydrogen can reap the additional benefits of knowing the levels of this volatile gas.

fast 1.0 bad ox sensor

The H 2 monitor allows each lab to optimize their Gas Mix consumption rate saving time and operational cost. Your anaerobic chamber becomes a dynamic environment in which you can readily determine leaks, bad catalyst or a need for change in equipment layout or airlock procedure. The CAM-12 (and it’s predecessor, the Model 10) Analyzer have been successfully used by researchers to monitor levels of the oxygen and hydrogen in their anaerobic chambers for over 25 years.

  • Detects real-time transient level changes.
  • The Coy Anaerobic Monitor (CAM-12) is the only analyzer that offers both O 2 (PPM) and H 2 (%) monitoring in one unit for the same price as most conventional Oxygen monitors.